 Embryo Cell Freezing Apparatus CL-8800i by AustraliaCRYOLOGIC The company manufactures a system for freezing biological samples with controlled temperature and rate and liquid nitrogen.

FREEZE CONTROL®There are series products, each system is modular. Each system includes a programmable programmed cooler, a freezer compartment and a freezer tank. The freezing chamber can be directly erected in the liquid nitrogen of the freezing tank, and can be connected to the program cooling meter to adjust the temperature of the sample. Users can select suitable components for configuration according to actual needs. Embryo Cell Freezing Apparatus

Users themselves can quickly set up the system, package it, and be portable.

Features:

The temperature can be set and maintained during operation.

Flexible Its rate can be changed according to the different requirements of the user. Cooling rates up8 ℃/Minutes.

Intelligent Temperature control is programmable and can also be temporarily set (when connected to a computer). When the temperature of the freezing tank is lower than the established temperature1.5 ℃when,

Security The system requires only a small amount of liquid nitrogen. There is no need to use liquid nitrogen cylinders, and other volatile or flammable liquids such as alcohol are not involved at all.

Economy The system consumes less liquid nitrogen per hour 1 litres, the consumption of electricity is less 60 Tile.

Reliable The operation is simple to use, and there is no need to monitor after setting.

Portable Compact structure design, small size, light weight, easy to use in the field.

Quiet The overall design of the system is such that no vibration or noise is generated.

The standard kit contains:1 × Program cooling instrument (programmable controller

1 × Standard freezer compartment (standard cryochamber

1 ×Standard liquid nitrogen tank (standard bath

1 ×Suitcase (carry case

Prefabrication procedure(CEP, preinstalled programs)or/and CGv5 Software(CryoGenesis V5 -software)

12) Program Cooler

FREEZE CONTROL Programed dethermometers provide reliable sample temperature regulation. The controller uses a service system to adjust the temperature of the sample to a preset temperature or set by a computer program by continuously variable heat flow.

The control range is suitable for most applications. If a temperature below a certain range is required, it can be passed.“freefall”, The controller will display the actual temperature. The controller can also provide a sample thawing function at a set rate. Temperature control accuracy is<± 0.1°C. 

The controller has optional power supply, exquisite power supply device. The temperature program of the controller may be preset or programmed. The controller of the preset program contains a built-in program chip containing the information needed to run the refrigeration system (CryoGenesis) through the computer to program.

 

 

CL-2200 Program cooling instrument

  

Control range:20°C to -43°C

Preset Program:Preset 8 temperature programs

Volume:90x155x175mm

Weight: 1.5kg

 

CL-3300Program cooling instrument

 

Control range: 40°C to -120°C

Preset Program:None

Data Interface: RS-232

Volume:90x155x175mm

Weight: 1.5kg

through software CryoGenesis™V4 or V5 to set the temperature control program. Suitable for research and teaching work.

 

CL-5500Program cooling instrument

 

 

There are built-in batteries available from the host, built-in batteries, and from external12VPower is obtained and can be applied in the field or in places without power supply.

Control range:20°C to -43°C

Preset Program:Preset 8 temperature programs

Volume:118x192x220mm

Weight:6kg (with battery)

 

 

CL-8800iProgram cooling instrument

 

Built-in temperature acquisition circuit

Control range:40°CTo-120°C

Preset Program: 16

Temperature setting:0.04°C

Data Interface: RS-232 and USB

Volume:90x195x225mm

Weight: 1.9kg

This system has built-in programs 16 It can also be done through software. CryoGenesis™ V4 and V5 to set the temperature control program. It includes a temperature recording module that can monitor the actual temperature progress and record it to the computer.

 

FREEZE CONTROL®The freezer compartment is suitable for a variety of applications. Each freezer compartment is separated and can be interchangeably connected with the controller.

Freezer room (CryoChambers) Including the following:

• Straw

• Security Straw

• 5-Slot Straw

• 5-Slot Bulb

• 60 Bulb

• Customer customization

Straw tube freezer (Straw CryoChamber

Straw CryoChamber

(Lid and stabilizer not shown)

 

central structure

 

Capacity:23 x 0.5ml or 46 x 0.25ml straw

Volume:55mm (diameter) x 150mm (height)

Weight:350g

 

freezing rate:Standard

20°C 时 8°C/min

-40°C 时 5°C/min

 

Product Number: CC23S

 

Fast

16°C/min

10°C/min

 

CC23F


Each slot contains:1 x 0.5ml straw, 2 x 0.25ml straw

 

Security Straw CryoChamber

 Security Straw CryoChamber

(Lid and stabilizer not shown)

 

 

central structure

Capacity:20 x CBS StrawsTMor 40 x 0.5ml or 60 x 0.25ml standard straw

Volume:55mm (diameter) x 150mm (height)

Weight:370g

freezing rate:

At 20°C

At -40°C

Product Number:

Each slot contains:1 x CBS StrawTM, 2 x 0.5ml straw, 3 x 0.25ml straw

 

Standard

7°C/min

4°C/min

CC20S

Fast

14°C/min

8°C/min

CC20F

If 0.5ml/0.25ml straw is used, it is recommend to use 2/3 straw per tank to ensure good thermal contact of the straw with the center wall.
 

 5-Slot Straw CryoChamber

  5-Slot Straw CryoChamber

  

(Lid and stabilizer not shown)

   

Capacity:55 x 0.5ml, 85 x 0.25ml straw or 45 x CBS strawsTM

Volume:55mm (diameter) x 150mm (height)

Weight:450g


Freezing rate:

At 20°C

At -40°C

Product Number:

Standard

6°C/min

3°C/min

CC5S

Fast

12°C/min

6°C/min

CC5F

 

Each slot contains:11 x 0.50ml straw, 17 x 0.25ml straw, 9 CBS strawsTM

Bulb as per 5-Slot Bulb Cryo Chamber

 

 

5-Cryo Chamber Bulb Slot

 

 

5-Cryo Chamber Bulb Slot

(Lid and stabilizer not shown)

   

central structure

 

Capacity:15 x 1.0ml, 10 x 2.0ml 或 5 x 5.0ml cryovials

Volume:55mm (diameter) x 150mm (height)

Weight:450g

Freezing Rate: Standard

20°C 时 6°C/min

-40°C 时 3°C/min

Product Number: CC5S

Fast

12°C/min

6°C/min

CC5F

Each slot holds: 3 x 1.0ml cryovials,2 x 2.0ml cryovials,1 x 5.0ml cryovial

60 Cryo Chamber Bulb

60 Cryo Chamber Bulb

(Lid not shown)

  

central structure

  

Capacity:60 x 1.0ml 或 60 x 2.0ml cryovials

Volume: 190 x 170 x 230mm

Weight: 1.5kg

Freezing Rate: Standard

20°C 时 3°C/min

-40°C 时 1.5°C/min

Product Number: CC60AS

Fast

5°C/min

3°C/min

CC60AF

Each slot can hold: 1 x 1ml

Cryovial,1 x 2ml Cryovial
If only a portion of the ampoule is frozen,They can be evenly distributed and contribute to the uniformity of heat transfer.
 
60 bulb cryochamberDesigned to carry 60 x 1.0ml screwtop (internalthread) ampoules (12 x 42 mm, ). Each ampoule is desirable. This freezer needs to be equipped 3.8liters of frozen tanks. It is designed to be used as an alternative to cryocooler freezing of bacterial cultures in microbiology laboratories and is suitable for the cryopreservation of plant and animal tissues where rate control is required.
Attachments:
1CryoChamberCover
 

CryoChamber There are three types of caps to suit different standard types of straw and ampoules:20mm High, suitable for most standard½Ml or¼ml strawand 1ml or 2ml Ampoules. (Product No.: SL

High Type:60mm high, suitable for extended½Ml or¼ml strawWhen it is used in 1.5 It needs to be modified when the liter of the frozen tank is on. (Product No.: TL

High Type:120mm High, suitable for double-length straw, also requires a modified freezer lid. (Product No.: VTL

2CryoChamber Sample Sampler (Specimen Lifters

 

FREEZE CONTROL®The freezer can be supplied with samplers to meet different applications:

23 Slot CoresSampler:

• Standard ½ ml & ¼ ml straw sampler (product number: L23)

• Short straw sampler (½ ml & ¼ ml)(product number: LC)

 5 Slot Coresof the straw sampler

• CBS straw sampler (product number: L35)

• ¼ ml straw sampler (17 straw each, product number: L85)

• ½ ml straw sampler (11 straws per lifter, article number: L55)

Ampoule sampler (1.0ml, 1.4ml, 1.8ml, 2.0ml & 5.0ml) product number: L5A

(3) Freezing tank (CryoBaths

 

FREEZE CONTROL®The CryoBaths in is used to preserve liquid nitrogen, and there are two models:

3.8 liters: After filling, it can meet the working time of 4 hours. User if needed60 Bulb

CryoChamberNeed to match this frozen tank.

Product Code: LNL

1.5 liters: fill can meet the working time of 2 hours.

  (4) Carrying case (Carry Cases

Horizontal carrying case

 

Can accommodate any standard with a 1.5 liter Cryobath

FREEZE CONTROL®System

Product Code: LNS

 

Erected carrying case

Standard system with 3.8-liter Cryobath possible

 

 

The carrying case can provide protection during transportation and storage, and the total weight is 915 kg (depending on different systems).
5) Built-in preset program
The built-in presets are generally determined by the user. These procedures need to include a starting (STARTING 2) Temperature(°C),and a state ( FINAL STATE Hold or FreeFall) . Note that the temperature is continuously monitored during the program./Display.
Each change needs to contain the rate of temperature change (RATE,°C/min), The target temperature (TARGET,°C),and a hold time(HOLD, min)The target temperature is maintained to the next change channel.
Each program can display some text to explain the application of a specific program, in. CL8800iThe program can be changed at the end of the special
Add one BELL (X) use sound to prompt (In Hold After time).
The following is an example:

 

FREEZE CONTROL Programs by
Chip Name: DEMO_WWW
For Model CL8800i

 

 
Rate
(
°C/min)
Target
Temp (
°C)
Hold Time
(min)
Bell
Program 0:
Human Embryo PrOH
Start Temp:
Final State:
24.0°C
FreeFall
2.00
- 7.0
1.0
X
0.00
- 7.0
9.0
 
0.30
- 60.0
0.0
X
Program 1:
Epidydimal Sperm
Start Temp:
Final State:
36.0°C
FreeFall
5.00
18.0
1.0
 
0.50
6.0
5.0
 
10.00
- 8.0
3.0
 
5.00
- 40.0
0.0
 
Program 2:
Embryos Bovine Ethylene Glycol
Start Temp:
Final State:
- 6.5°C
Hold
0.00
- 6.5
8.0
 
0.50
- 35.0
0.0
 
Program 3:
Placental Blood  Glycerol
Start Temp:
Final State:
33.0°C
FreeFall
4.00
4.0
5.0
 
2.00
- 8.0
4.0
 
0.65
- 120.0
0.0
X
 
 
When the status is set Hold, the program cooler will maintain the set temperature until the program is interrupted or the liquid nitrogen is exhausted.
When the final state is FreeFall,The controller will always drop from the set temperature towards the temperature of liquid nitrogen (-196°CDescending
The rate of temperature is determined by the sample temperature, cavity and load.
If you need more information on how to design the program, please contact CryoLogic Contact.
Programs can be replaced. The new program can be installed on the program chip, remove the original chip on the device, and replace it with a new one. Attention:Program chips are not interchangeable between different models.
(6)Temperature Control Procedure

CryoGenesis V5 Features:

Individualized temperature control program can be prepared

The execution of the program is monitored and controlled

Information on the freezing operation is also recorded

Freezing operation can be started quickly and easily

Can display the recorded freezer (Cryochambertemperature in)

The history of all past freezing operations can be maintained.

CG V5 available in Windows 95, 98, ME, NT, 2000 and XP It runs under the operating system and can execute other programs at the same time.

CryoGenesis™ V4

CryoGenesis™ V4 The temperature control software is controlled CryoLogic developed, FREEZE CONTROL®Can

 

 

Programming program cooling instrument (CL-8800i, CL-3300).

 CryoGenesis V4The characteristics:

Individualized temperature control program can be prepared

The execution of the program is monitored and controlled

The recorded temperature in the freezer compartment (Cryochamber) can be displayed.

CG V4 can run under Windows 3.1, 95, 98, or ME operating systems, and can run other programs at the same time.

 

Accessories:

 

Technical parameters:

 

Parameters

CL8800i

CL5500

CL3300

CL2200

Temperature control range

40~ -120

20~ -43

40~ -120

20~ -43

Temperature display

digital liquid crystal displayThe resolution is0.1

digital liquid crystal displayThe resolution is0.1

None

None

Built-in program

16One

16One

None

None

Minimum temperature step

 

0.04

 

-------

 

------

 

------

Communication Interface

RS232orUSB

 

-------

RS232orUSB

 

------

Thermometer use temperature

 

------

 

40~ 0

 

------

 

------

Weight

1.9kg

6kg(including battery pack)

1.5kg

1.5kg

Overall dimension

90*195*225mm

118*192*220mm

90*155*175mm

90*155*175mm  

 

Key words:

Scientific equipment

Get Quote

We will contact you within one working day. Please pay attention to incoming calls from your mobile phone.


Get Quote

Get Quote


We will be happy to provide you with quality products and services