Australian MTI PDV6000 Water and Food Heavy Metal Analyzer
Category:
Brand:
Model:
Product Information
Australia MTI PDV6000 water quality and food heavy metal analyzer is widely used to detect the heavy metal content in soil, food, solid waste and other solid substances, and can detect the concentration of chromium, cadmium, copper, arsenic, mercury, lead, zinc, antimony, iron and other metal ions. For water as the main component of the liquid, has been widely used in drinking water, drinking water sources, surface water, beverages, environmental water monitoring.
Product features:
• PDV6000 heavy metal analyzer is a rapid heavy metal ion concentration determination tool, the state of the measured object is liquid, for solid samples;
• The PDV6000 uses the principle of anodic stripping (ASV) to detect heavy metal ions in the sample without high-pressure gas, flame, atomic lamp; the experiment is simple;
The detection time only takes 20-300 seconds, and the preparation before detection takes several minutes.
• Detection range from 4ppb to 300ppm
Australian MTI PDV6000 Water and Food Heavy Metal AnalyzerThe concentration of chromium, cadmium, copper, arsenic, mercury, lead, zinc, antimony, iron and other metal ions can be detected by software settings
• Faster than traditional methods. The controller can be programmed with more than 10 analytical methods, and can detect 4 kinds of heavy metals at the same time;
• stand-alone operation, PDV 6000 accuracy of 10%, when connected with a computer to use Windows applications;
• PDV6000 easy to carry, can be used for laboratory or field testing
• The instrument can be used stand-alone or connected to a computer, with a set of software to control the detection process
• When in the field, a rechargeable NiMH battery ensures power supply. Data is displayed on the screen and can be stored by computer
• PDV 6000 consists of a reaction box and a controller, the reaction box (cell) constitutes an electrolytic cell, and the controller controls the reaction process and detects
• PDV 6000 if used to determine water accounted for the main components of the liquid, the operation process is simple and convenient
• Has been widely used in drinking water, drinking water sources, surface water, beverages, environmental water monitoring
• PDV6000 has been widely used to detect the content of heavy metals in soil, food, solid waste and other extracts
• The characteristics of PDV 6000 make it outstanding for field and emergency detection
Australian MTI PDV6000 Water and Food Heavy Metal AnalyzerTechnical parameters:
Detection method of arsenic in fresh water (5-500ppb)
Method for determination of cadmium in fresh water (5-500ppb)
Method for determination of lead in fresh water (5-500ppb)
Method for determination of copper in fresh water (5-500ppb)
Method for determination of antimony in fresh water (5-500ppb)
Detection method of chromium in fresh water (5-500ppb)
Method for determination of iron in fresh water (5-500ppb)
Detection method of silver in freshwater (5-500ppb)
Method for determination of tin in fresh water (5-500ppb)
Detection method of TUO in fresh water (5-500ppb)
Detection method of selenium in fresh water (5-500ppb)
Method for determination of cadmium, lead and zinc in natural water (5-500ppb)
Determination of cadmium, lead and copper in seawater (5-500ppb)
Determination of cadmium, lead and copper in sewage (5-500ppb)
Food:
Determination of cadmium, lead and copper in common foods
Determination of cadmium in oysters and mussels
Determination of cadmium and lead in wine
Detection method of cadmium in wheat
Australia MTI PDV6000 water quality and food heavy metal analyzer technical parameters:
|
Controller |
Control the reaction process, and detection, display |
|
Reaction Box |
(cell) reaction space for electrolysis (anodic stripping voltammetry) |
|
Software |
VAS Software |
|
Detection range |
1ppb-300ppm |
|
Detection method |
anodic stripping voltammetry |
|
Resolution |
0.1ppb |
|
Indication precision |
1ppb |
|
Calibration mode |
Standard sample calibration |
|
Detection time |
30 seconds |
|
Type of detection method |
12 species |
|
software analysis function |
10 Programmable Analysis Menus |
|
Communication Interface |
RS-232 |
|
Reaction box (cell) |
Reaction space for electrolysis |
|
Resolution |
1ppb |
|
Main power supply |
220VAC |
|
Field power supply |
Rechargeable battery
|
Technical parameters
| Reaction box (cell): | Reaction space for electrolysis |
| Controller size: | W x L x D: 10 x 18 x 4 m |
| Detection range | 1 ppb -300 ppm |
| Resolution | 1ppb |
| Detection accuracy | +/- 3 % at 100 ppb |
| Calibration mode | Standard sample calibration |
| Detection time | 30 seconds |
| The method provided by the manufacturer can detect the type. | 12 species |
| software analysis function | 10 Programmable Analysis Menus |
| Communication Interface | RS-232 |
| Main power supply | 220V AC |
| Field power supply | Rechargeable battery |
| Dimensions | 10cm × 18 cm × 4 cm |
| Detectable heavy metal ion species | Cr (chromium), Mn (manganese), Fe (iron), Co (cobalt), Ni (nickel), Cu (copper), Zn (zinc), As (arsenic), Se (selenium), Pd (palladium), Ag (silver), Cd (cadmium), Sn (tin), Sb (antimony), Te (tellurium), Au (gold), hg (mercury), Tl (thallium), Pb (lead), Bi (bismuth) |
| Specific detection range | 锌:1 ppb -32 ppm : 1 ppb -300 ppm 镉:1 ppb -30 ppm :1 ppb -300 ppm 铜:1 ppb -32 ppm : 1 ppb -8 ppm : 1 ppb -6000 ppb 锰:1 ppb -30 ppm : 1 ppb -20 ppm |
Key words:
Scientific equipment
Get Quote
We will contact you within one working day. Please pay attention to incoming calls from your mobile phone.